Cordilla is manufactured according to your wishes. You select performance, length, way of mounting, connection positions, colour and more with the help of the product key. Three types of recessed mountings are available. Other adaptions may be possible, please contact us.
Performance | Length | Heat | Mounting | Recessed | Water connection | Electrical connection | Colour |
---|---|---|---|---|---|---|---|
35 | 10 | WL | H (standard) | X (standard) | A (standard) | A | RAL Classic (standard) |
45 | 15 | WLL | VL | ZDS | B | B (standard) | |
20 | E | VR | ZDA | C | C | ||
25 | A | ZDE | D | D | |||
30 | X* (standard) |
* State X for units with Electrical heating or Ambient (without heat).
See example below: CDL4520WL - H - ZDS - B - A - RAL9010 is a 2-meter, water heated Cordilla 4500 with WL coil for horizontal recessed mounting according to drawing ”ZDS”. The water connections are on the top to the right (B) and the electrical connection is on the top to the left (A). It is painted white RAL9010.
Performance | Length | Heat | Mounting | Recessed | Water connection | Electrical connection | Colour |
---|---|---|---|---|---|---|---|
45 | 20 | WL | H | ZDS | B | A | RAL9010 |
WL: Water heating, WL coil
WLL: Water heating, WLL coil
E: Electrical heating
A: Ambient (without heat)
H: Horizontal
VL: Vertical left, seen from inside
VR: Vertical right, seen from inside
If several units are to be mounted directly next to each other, please state this when ordering.